Brand Name: TAQU
Model Number: T-WFS
Place of Origin: China
Features
- Suitable for water, ethylene glycol or other pipelines not classified as hazardous liquids
- Medium Temperature 0-90 ℃
- The maximum working pressure can reach 1.0 MPa.
- Flow value control is adjustable and repetitive action point is stable.
- It can adjust the number of blades and trim the length of blades.
- In order to meet the requirements of different pipe diameters and flow velocities.
Application
- Applied in places where chain action or "cut-off" guarantees are required
-Water circulation control, water inlet and outlet control, water pump switch control of water system,
Solenoid valve on-off control or outflow power-off, outflow power-on control, etc.
Parameters
Working Voltage: |
125~250V AC |
|||||||||||||||||||
Adjustment Range: |
6~1800L/min |
|||||||||||||||||||
Proof Pressure |
1.6MPa |
|||||||||||||||||||
Medium Temperature |
0~90℃ |
|||||||||||||||||||
Working Medium |
Water, oil or other non-corrosive liquid to copper |
|||||||||||||||||||
Working Environment |
5~50℃ |
|||||||||||||||||||
Cable Specifications |
24~18AWG(0.2~1.0mm2),Strip length 6-7mm |
|||||||||||||||||||
Contactor Capacity |
AC.250V.10A(Resistance) 1 Change-over Contactor(normally open or close)
|
|||||||||||||||||||
Electrical Rating |
|
|||||||||||||||||||
Pipe Diameter |
DN32~200mm |
|||||||||||||||||||
Thread Interface |
3/4",1" |
|||||||||||||||||||
Target |
A full set of 5, selection according to the control requirements ( refer to the following table) |
|||||||||||||||||||
Net Weight |
370g /0.85lb |
Pipeline and Flow Regulation Reference Table:
No. |
Flow Range |
Switching Difference |
Repetitive Error L/min |
Pipe Diameter |
Target No. |
Max Allowable Working Pressure MPa |
|
in |
mm |
||||||
1 |
20~48 |
8 |
1.1 |
1 |
25 |
1 |
1.6 |
2 |
34~100 |
10 |
2.6 |
11/4 |
32 |
1 |
|
3 |
65~160 |
14 |
3.8 |
11/2 |
40 |
1 |
|
4 |
120~280 |
26 |
6.4 |
2 |
50 |
1 |
|
5 |
40~140 |
18 |
4.0 |
2 |
50 |
1+2 |
|
6 |
210~550 |
18 |
|
21/2 |
70 |
1 |
|
7 |
110~340 |
15 |
|
21/2 |
70 |
1+2 |
|
8 |
380~750 |
20 |
|
3 |
80 |
1 |
|
9 |
180~470 |
18 |
|
3 |
80 |
1+2 |
|
10 |
115~220 |
20 |
|
3 |
80 |
1+2+3 |
|
11 |
350~920 |
20 |
|
4 |
100 |
1+2 |
|
12 |
210~590 |
20 |
|
4 |
100 |
1+2+3 |
|
13 |
380~1200 |
40 |
|
5 |
125 |
1+2+3 |
|
14 |
550~1800 |
80 |
|
6 |
150 |
1+2+3 |
Notes:1. No. 6-14 is reference; 2. setting value is down-switching value.
Full Set Target:
P1=35, P2=59, P3=90, P4=120, P5=150mm
SPDT Micro-operation Switch Working Status:
When flow rises to the top switching value, C-A is connected;
when flow falls to the bottom switching value, C-B is connected.
Ordering Information
Series |
Thread |
|
T-WFS- |
3/4″ 1″ |
(C2) (C3) |
- Note: When ordering, please specify the product series and parameter functions. For other parameters, please refer to "Pipeline and Flow Regulation Reference Table".